Roots blower fault causes the gear of roots blower not working

Source: Roots blower manufacturer Published on: December 21, 2021 Hits:
The gear pair of Roots blower is generally supported by 45 steel. The gear pair of two blade roots blower is not only a pair of transmission gears, but also a pair of synchronous gears. Only when the two gears have the same angle of rotation, can the two impellers of roots blower operate normally. Otherwise, the two impellers will collide and damage the normal operation of the blower, or even cause equipment accidents.
Most gear pairs on driven shaft of Roots blower are made of gear ring and gear hub assembly. The clearance between impellers can be achieved by adjusting the driven gear ring. During adjustment, it is only necessary to remove the locating pin and rotate the screw, that is, rotate the moving gear ring to adjust the impeller clearance. After the clearance is adjusted, tighten the fastening screw, drill and ream the locating pin hole again, and install a new locating pin.
The gear backlash shall not be greater than or equal to the tooth clearance of two blade gears during design. Practice has proved that when the gear backlash is more than two-thirds of the impeller clearance, the two impellers will collide during operation. In this case, the two cogged gears need to be updated or readjusted.
The gear and shaft adopt high precision transition fit, and the key used to fix the gear adopts special tolerance fit to prevent the gear key from loosening, so that the gear can be tightly fixed on the shaft, so as to prevent the gear backlash from increasing once the gear is loose, so that the two impellers will collide.
First, the bearing is damaged.
The damaged bearing bush will also cause the gear to be unable to rotate. The bearing bush is an important part of Roots blower. Each Roots blower head has four bearing bushes, which are placed at both ends of the impeller shaft. The bearing bush is damaged, the impeller is jammed, and the gear is jammed. Therefore, this also causes the gear to be unable to rotate.
The second rotating shaft is damaged.
The rotating shaft is a part of the impeller, which runs through the horizontal shaft of the impeller. Some rotor shafts are integrally formed and some are assembled together. The wear and deformation of rotor shafts will affect the rotation of impeller and gear.
Third, if the meshing clearance is too small, the gear cannot rotate, and the clearance standard of the root fan assembly is high, it needs to be adjusted according to the design requirements.
 Causes of Roots blower gear not working
4、 The positioning hole is out of alignment.
After the roots blower is overhauled, if the impeller and shaft are replaced, the positioning of the gear sleeve may be inaccurate. If the positioning of the gear sleeve is inaccurate, the hole needs to be redesigned according to the position of the gear. If the positioning is incorrect, install the gear, and the gear will rotate unstably.
5、 The impeller is stuck.
The impeller of Roots blower is damaged. Both the gear and the impeller are located in two boxes. The reason for the damage to the gear may be the failure of the impeller, or the failure to check the impeller after installation, which causes the gear not to move. This situation may be due to the failure of the impeller during rotation.
I believe that after reading the above content, you should also understand the reason why the Roots blower gear does not work. I hope it will help you.