Notes on installation of safety valve of three blade roots blower

The safety valve of three leaf roots blower shall be installed vertically and close to the protected equipment or pipeline. If it cannot be arranged near, the total pressure drop of the pipeline from the protected equipment or pipeline to the inlet of the safety valve shall not exceed 3% of the constant pressure value of the safety valve.

The safety valve of three blade roots blower should be equipped with a maintenance platform. When arranging the safety valve with large weight, the possibility of lifting after the safety valve is disassembled shall be considered, and the suspender shall be set if necessary. Long radius elbow shall be used for inlet pipe of safety valve of three blade roots blower.

The design of the outlet pipeline of the safety valve of the three blade roots blower shall consider that the back pressure does not exceed a certain value of the constant pressure of the safety valve. For ordinary spring type safety valve, its back pressure shall not exceed 10% of the constant pressure value of the safety valve.

When the medium discharged into the vent header or flare header contains condensate or condensable gas, the outlet of the safety valve shall be higher than the header; Otherwise, drainage measures shall be taken.

The outlet pipeline of the safety valve discharged into the closed system shall be mitered at the top of the discharge header at 45 ° along the flow direction of the medium, so as to prevent the condensate in the header from flowing back into the branch pipe, and reduce the back pressure of the safety valve. When the inlet and outlet pipelines of the safety valve of the three leaf roots blower are equipped with a shut-off valve, the single gate valve shall be selected and lead sealed, and the valve rod shall be installed horizontally, To prevent the valve plate from sliding down when the pin connecting the valve rod and the valve plate is corroded or loose.

When the safety valve is equipped with a bypass valve, the valve shall be lead sealed off.