Precautions for lubricating oil replacement of Roots blower: Roots blower is used for many purposes, usually on construction sites or factories. How to maintain the service life of Roots blower and how often to change the lubricating oil? Let's take you to analyze?

In fact, it is normal to change the oil and grease for the first time when Roots blower runs for about 200 hours, and for the second time after a month of operation. In the future, the oil (grease) shall be replaced according to the service environment and oil (grease) quality. It is recommended to replace it every three months; When the oil temperature exceeds 50 degrees. It is recommended to replace it once a month. CKC-N320 medium load industrial gear oil can also be used.

After the Roots blower is put into operation, the small editor recommends replacing all lubricating oil after 8 hours of operation. What precautions will be taken? The first step is to remove the gear oil and then inject new gear oil. The first time: one month after operation, the second time after three months, and once every six months for long-term operation. Pay attention to the oil level at ordinary times and replenish it in time.

2. Evaluation of lubricating oil quantity of Roots blower: The gear side oil mirror can be seen at any time for the oil volume of each model of Roots blower, and the oil level can be kept between the center line during shutdown. When the oil level is lower than the middle position, add lubricating oil in time. If the oil level is higher than the middle position, high oil temperature, tail gas injection, gas leakage, etc. may occur.

3. Storage of Roots blower lubricating oil: After the gear oil is injected, the rest of the gear oil cannot be directly exposed to prevent other pollutants from entering the barrel, which may cause oil contamination. Secondly, the oil should be kept away from the fire source and the digestion equipment should be placed. Tighten the cover after use to keep the oil drum sealed. The new oil and waste oil shall be placed separately, and the container for waste oil shall not be filled with new oil to prevent pollution.