How to solve the stop of Roots blower?

Source: Roots blower manufacturer Released on: December 2, 2023 Hits:

How to solve the stop of Roots blower? When the roots blower stops running, cut off the power supply and stop running in time, take corresponding maintenance measures, and start the standby roots blower to avoid potential production losses. The following are several common reasons that may cause the Roots blower to stop running, which need to be carefully checked and solved.

Foreign matter stuck:

Possible cause: Large particles of foreign matter enter the fan cavity, blocking the gap between components.

Solution: Clean the foreign matters in the cavity after cutting off the power supply and check the clearance between impellers. Find out the cause of foreign matter entering to prevent it from happening again.

Impeller damage:

Possible cause: The fan cannot rotate normally due to damaged impeller.

Solution: Disassemble and check the shell, repair or replace the damaged impeller, and ensure the normal engagement between impellers.

Gear damage:

Possible cause: The occluded area of gears is greater than the normal value, which leads to too large meshing force between gears and failure of normal rotation.

Solution: Disassemble and check, repair or replace the damaged gear. Adjust the blocking area to the normal range to ensure the normal operation of the gear.

When dealing with the stop of Roots blower, carefully check the possible causes according to the specific situation and take corresponding solutions. Timely repair and maintenance will help ensure the normal operation of Roots blower and improve production efficiency.

The above is the details of "How to solve the problem of Roots blower stalling?" I hope it can help you